Magnetic flap level gauges are usually available in the market due to their different environments and usage requirements.



normal type

Withstand the maximum working pressure: normal pressure (1.0Mpa or less)

Maximum working temperature: 80 ° C

Measuring range: 0~12m

Measuring medium density: 0.5~1.8 g/cm3

Default process connection: flange connection

Display panel installation default orientation: forward facing flange



Anti-corrosion type

Withstand maximum working pressure: 10Mpa or less

Maximum working temperature: 80 ° C

Measuring range: 0~12m

Measuring medium density: 0.5~1.8 g/cm3

Default process connection: flange connection

Display panel installation default orientation: forward facing flange



Heating type

Withstand maximum working pressure: below 10Mpa

Maximum working temperature: 200 ° C

Measuring range: 0~12m

Measuring medium density: 0.5~1.8 g/cm3

Default process connection: flange connection

Display panel installation default orientation: forward facing flange



Frostproof

Withstand maximum working pressure: below 10Mpa

Maximum working temperature: 80 ° C

Measuring range: 0~12m

Measuring medium density: 0.5~1.8 g/cm3

Default process connection: flange connection

Display panel installation default orientation: forward facing flange



High temperature type

Withstand maximum working pressure: below 10Mpa

Maximum working temperature: 200 ~ 450 ° C

Measuring range: 0~12m

Measuring medium density: 0.5~1.8 g/cm3

Default process connection: flange connection

Display panel installation default orientation: forward facing flange



High pressure type

Maximum working pressure: over 10MPa (31 MPa or less)

Maximum working temperature: 200 ° C

Measuring range: 0~6m

Measuring medium density: 0.5~1.8 g/cm3

Default process connection: flange connection

Display panel installation default orientation: forward facing flange



High temperature and high pressure type

Maximum working pressure: over 10MPa (20 MPa or less)

Maximum working temperature: 200 ~ 450 ° C

Measuring range: 0~6m

Measuring medium density:

Default process connection: flange connection

Display panel installation default orientation: forward facing flange



Explosion-proof

Withstand maximum working pressure: 10Mpa or less

Maximum working temperature: 120 ° C

Measuring range: 0~12m

Measuring medium density: 0.5~1.8 g/cm3

Default process connection: flange connection

Display panel installation default orientation: forward facing flange



Top type

Withstand the maximum working pressure: 1.6MPa

Maximum working temperature: 200 ° C

Measuring range: 0~12m

Measuring medium density: 0.5~1.8 g/cm3

Default process connection: flange connection

Display panel installation default orientation: forward facing flange



Related products: metal rotameter , magnetic flap level gauge , two-color quartz tube level gauge , plastic tube float flowmeter