Warm and maintenance can not despise some details
First, pay attention to floor insulation during installation
When using geothermal floors, consumers must pay attention to the gradual heating of floors and floors. When installing, the surface temperature should be maintained at about 18°C. Before installation, gradually increase the temperature of the concrete floor by 5°C per day until it reaches the standard of about 18°C. In the first 3 days after the installation is completed, the temperature should be maintained. After 3 days, the temperature can be increased as needed, and the temperature can only be increased by 5°C per day.
Second, pay attention to warming step by step
Geothermal heating is used for the first time, and attention should be paid to increasing the temperature slowly. When used for the first time, gradually increase the temperature in the first three days of heating: the first day of water temperature is 18°C, the next day is 25°C, the third day is 30°C, and the fourth day can be raised to normal temperature, ie, water temperature 45°C, surface temperature 28 °C ~ 30 °C. Can not warm up too quickly, too fast, the floor may be cracked due to expansion.
Third, restart after a long time, warming should also be gradual
When the geothermal heating system is turned on again for a long time, it must be used like the first time. The surface temperature should not be too high by strictly following the heating and heating procedures.
It should be noted that with geothermal heating, the surface temperature should not exceed 28°C, and the temperature of the water pipes should not exceed 45°C. If this temperature is exceeded, the service life and life cycle of the floor will be affected. In general families, when the room temperature in winter reaches about 22°C, it is already very comfortable. If the temperature rises normally, it will not affect the use of geothermal floors. Close the geothermal system, pay attention to gradual cooling
With the passage of the seasons, when the weather is warm and indoors no longer requires geothermal heating, attention should be paid to shutting down the geothermal system. There must also be a process of cooling down the floor. The cooling process of the floor must also be gradual, not abruptly reduced, if the cooling rate is too fast, It will also affect the life of the floor.
Four, when the room is too dry, you can consider humidification
In winter, the climate is dry, and geothermal heating is used. If the floor is exposed to high temperatures for a long time, it will be easy to crack. At this time, the owner must humidify the room so as not to crack the floor.
Del floor nature floor cement heating space room paint fashion small apartment